How To Set Honeywell Programmable Thermostat
Honeywell Programmable Thermostat Owner's Manual
Honeywell Programmable Thermostat Owner'southward Manual
This is a legacy product document supported past Resideo. It is no longer manufactured
Read and salvage these instructions.
For help please visit: yourhome.honeywell.com
Installation is Piece of cake
- Characterization wires and remove your former thermostat
- Install and wire your new thermostat
- Set up your new thermostat to match your heating/cooling system
- Information technology is preset for the most common arrangement
Do you need assistance? We are here to assistance.
Telephone call one-800-468-1502 for wiring aid earlier returning the thermostat to the shop.
Attention: MERCURY RECYCLING Notice
This product does not contain mercury. However, this production may replace a product that contains mercury. Mercury and products containing mercury should not be discarded in household trash.
For more information on how and where to properly recycle a thermostat containing mercury in the United states of america, delight refer to the Thermostat Recycling Corporation at www.thermostat-recycle.org.
For mercury thermostat recycling in Canada, please refer to Switch the Stat at world wide web.switchthestat.ca
Turn Off Power to Heating/Cooling System
Remove Old Thermostat
Remove old thermostat merely leave wallplate with wires attached.
Label the wires using the supplied wire labels equally yous disconnect them.
Split Wallplate from New Thermostat
Remove wallplate from the new thermostat and mount onto wall.
Wallplate
Mountain Wall plate
Mount the new wall plate using the included screws and anchors.
Drill 3/16-in. holes for drywall
Drill 3/32-in. holes for plaster
Connect Wires
Only match wire labels.
If labels practise non match letters on the thermostat, check Alternate Wiring on page 6 and connect to final as shown (see notes, beneath).
We are here to help. Call 1-800-468-1502 for wiring assistance.
Alternate Wiring (Conventional Systems)
If labels do not lucifer terminals, connect wires every bit shown here (see notes, beneath).
Wiring—Oestrus Pump
If E and Aux do not each accept a wire connected, use a small piece of wire to connect them to each other.
Alternate Wiring (Rut Pump Merely)
If labels practise not match letters on the thermostat, check the chart below and connect to terminal as shown here (see notes, beneath).
Install Batteries
Install Thermostat onto Wallplate
Install thermostat onto the wall plate on the wall.
Turn Power Back On
Plough the power dorsum on to the heating/cooling arrangement.
If your system type is:
- Single Phase Oestrus and Cool
Congratulations, y'all're done!
If your system type is:
- Multistage Rut and Cool
- Rut Pump* without Fill-in Heat
- Heat Pump* with Backup Rut
- Heat Simply
- Absurd But
Proceed with Advanced Installation to friction match your thermostat to your system type.
*Heat Pump—an air conditioner that provides cooling in the summer, and also runs in contrary in the wintertime to provide heating.
If y'all are not sure of your organisation type or if y'all have other questions, call usa toll-gratuitous at 1-800-468-1502.
This thermostat works on 24 volt or 750 mV systems. Information technology will Non work on 120/240 Volt systems.
Advanced Installation
Enter Organization Setup
To enter organisation setup, printing and hold both the ▲ and FAN buttons until the display changes (approximately 5 seconds).
Changing Settings
- Printing the ▲ or ▼ button to alter the setting.
- Press NEXT to advance to the next function.
- Press DONE to go out and salve settings.
About your new thermostat
Your new Honeywell thermostat has been designed to give you many years of reliable service and easy-to-use, push button-push climate command.
- Easy-to-follow menu programming.
- Ane-touch temp control overrides plan schedule at any time.
- Big, clear, backlit brandish is easy to read — fifty-fifty in the dark.
- Displays both room temperature and temperature setting.
- Removable battery holder for fast, like shooting fish in a barrel replacement.
- Built-in compressor protection.
Thermostat controls
Display screen
Set the fourth dimension and mean solar day
- Press Gear up CLOCK/Twenty-four hour period/SCHEDULE, then press ▲ or ▼ to set the clock time.
- Press the Fix DAY button, so press ▲ or ▼ to select the solar day of the week.
- Press Washed to relieve & exit.
Notation: If the Prepare CLOCK/24-hour interval/SCHEDULE pick is not displayed, press Done or RUN SCHEDULE.
NOTE: If the display flashes Set Clock, the thermostat will follow your settings for the weekday "Wake" time menstruum until you reset the time and twenty-four hour period.
Program Schedule
You can program four time periods each day, with dissimilar settings for weekdays and weekends. Nosotros recommend the pre-set settings (shown in the table below), since they can reduce your heating/ cooling expenses.
Wake – Fix to the time you lot awaken and the temperature you desire during the morning, until y'all leave for the 24-hour interval.
Go out – Set to the time you leave home and the temperature yous want while y'all are away (normally an energy-saving level).
Return – Gear up to the time you return home and the temperature you want during the evening, until bedtime.
Sleep – Set to the fourth dimension you go to bed and the temperature you want overnight (usually an energy-saving level).
NOTE: Leave and Render periods can be canceled on weekends
To adjust program schedules
(RTH6350 and RET93E just)
- Press SET CLOCK/Solar day/SCHEDULE, then Ready SCHEDULE.
- Press ▲ or ▼ to gear up your weekday Wake time (Mo-Fr), then press Next.
- Printing ▲ or ▼ to set the temperature for this time period, and then press Adjacent.
- Set up fourth dimension and temperature for the next fourth dimension period (Leave). Repeat steps 2 and 3 for each weekday time period.
- Press NEXT to set up weekend time periods (Sa & Su), then press Done to save & exit.
NOTE: Make sure the thermostat is set to the system y'all want to plan (Heat or Cool).
Notation: You can printing CANCEL PERIOD to eliminate unwanted time periods (except Wake).
To adjust program schedules
(RTH6450 and RET95E but)
- Press Gear up CLOCK/Mean solar day/SCHEDULE, and so Gear up SCHEDULE.
- Press ▲ or ▼ to set your weekday Wake time (Mo-Fr), then press Side by side.
- Printing ▲ or ▼ to set the temperature for this time flow, then press Adjacent.
- Ready time and temperature for the next fourth dimension period (Exit). Repeat steps 2 and 3 for each weekday time period.
- Press Side by side to set up Saturday fourth dimension periods.
- Printing Adjacent to gear up Sunday time periods, then press DONE to save & exit.
NOTE: Make sure the thermostat is ready to the system y'all want to program (Oestrus or Cool).
Note: You can printing CANCEL PERIOD to eliminate unwanted time periods (except Wake).
Program schedule override (temporary)
Press ▲ or ▼ to immediately adjust the temperature. This will temporarily override the temperature setting for the current fourth dimension menstruum.
"Temporary" will appear on the brandish and the electric current program period volition flash.
The new temperature volition be maintained only until the next programmed fourth dimension catamenia begins (see page xiii).
To cancel the temporary setting at any time, printing RUN SCHEDULE.
NOTE: Brand certain the thermostat is fix to the organization yous want to control (heat or cool).
Programme schedule override (permanent)
Press Concord to permanently accommodate the temperature. This will override the temperature settings for all time periods.
The "Concur" feature turns off the program schedule and allows you to conform the thermostat manually, every bit needed.
Any temperature yous prepare volition be maintained 24 hours a twenty-four hour period, until you lot manually change information technology, or press RUN SCHEDULE to cancel "Concur" and resume the program schedule.
Note: Make sure the thermostat is set to the system you want to control (heat or cool).
Auto Changeover (RTH6450 and RET95E only)
Use this feature in climates where both air conditioning and heating are used on the same solar day. When the organization mode is in Auto, the thermostat automatically selects heating or cooling depending on the indoor temperature.
While in the Auto way, if a schedule override takes place (temporarily or permanently) the thermostat will automatically arrange the cooling and heating settings to maintain a 3-degree separation between the absurd and heat settings.
For example, if the heat temperature is raised to where it gets within iii-degrees of the cool setting, the display will bear witness an upwards arrow side by side to "cool" to bear witness the thermostat is raising the absurd setting upwardly to maintain a 3-degree separation.
Press the Select Heat/Cool button to select between the heat and cool to view/suit either mode.
NOTICE: To avoid possible compressor harm, do not use Auto Changeover if the outside temperature drops below 50ºF (10ºC).
Smart Response® Engineering
Smart Response® Engineering science: This feature allows the thermostat to "larn" how long the furnace and air conditioner have to achieve programmed temperature settings, and so the temperature is reached at the time you set. For example: Set the Wake fourth dimension to 6 am, and the temperature to seventy°. The heat will come on before 6 am, so the temperature is seventy° by the time y'all wake at 6. The bulletin "In Recovery" is displayed when the system is activated earlier a scheduled time period.
Built-in compressor protection
This feature helps prevent harm to the compressor in your air conditioning or heat pump system.
Impairment can occur if the compressor is restarted as well before long after shutdown. This characteristic forces the compressor to wait a few minutes before restarting.
During the wait fourth dimension, the display will flash the message Cool On (or Rut On if you have a estrus pump). When the safety wait fourth dimension has elapsed, the message stops flashing and the compressor turns on.
Battery replacement
Install fresh batteries immediately when Supervene upon BATTERY begins flashing. The warning flashes virtually two months earlier the batteries are depleted.
Replace batteries one time a year, or when you volition be away for more than a month.
If batteries are inserted within two minutes, the time and mean solar day volition not take to exist reset. All other settings are permanently stored in memory and do non require battery power.
Troubleshooting
If you take difficulty with your thermostat, delight try the following suggestions. Virtually problems can exist corrected quickly and hands.
- Display is bare: Make sure fresh AA alkaline batteries are correctly installed
- Temperature settings practice non change: Brand sure heating and cooling temperatures are ready to adequate ranges:
• Heat: 40° to 90°F (iv.5° to 32°C).
• Cool: l° to 99°F (10° to 37°C). - Cannot change organisation setting to Cool
• Check Function 1: Organization Type to make sure it is gear up to friction match your heating and cooling equipment - Fan does not plow on when heat is required
• Check Function 3: Heating Fan Control to brand sure it is set to match your heating equipment - Heating or cooling arrangement does not respond
• Press SYSTEM button to prepare system to Heat. Brand certain the temperature is fix higher than the Inside temperature.
• Printing Arrangement button to gear up system to Cool. Make sure the temperature is gear up lower than the Within temperature.
• Check circuit billow and reset if necessary.
• Make sure ability switch at heating & cooling system is on.
• Brand certain furnace door is closed securely.
• Expect 5 minutes for the system to respond. - "Cool On" or "Heat On" is flashing
• Compressor protection feature is engaged. Await 5 minutes for the system to restart safely, without damage to the compressor - Heat pump issues cool air in heat fashion, or warm air in cool way
• Check Role 2: Heat Pump Changeover Valve to make certain it is properly configured for your arrangement. - Heating and cooling equipment running at the same time (or estrus does non plow off)
• Check Office 1: System Type to make certain information technology is fix to friction match your heating and cooling equipment.
• Grasp and pull thermostat abroad from wallplate. Bank check to brand sure blank wires are not touching each other. - Heating arrangement is running in absurd mode
• Check Function one: System Type to make sure it is set to lucifer your heating and cooling equipment
For assistance with this product, please visit http://yourhome.honeywell.com or call Honeywell Client Intendance toll-free at 1-800-468-1502.
Warranty
Honeywell warrants this product, excluding bombardment, to exist complimentary from defects in the workmanship or materials, under normal use and service, for a flow of 1 (1) yr from the date of buy by the consumer. If at whatsoever time during the warranty menstruation the product is determined to be defective or ma functions, Honeywell shall repair or replace it (at Honeywell's choice).
If the product is defective, (Honeywell Programmable Thermostat)
- return information technology, with a beak of auction or other dated proof of purchase, to the place from which
yous purchased it; or - call Honeywell Client Care at ane-800-468-1502. Customer Care volition make the determination whether the production should exist returned to the post-obit address:
Honeywell Return Goods, Dock 4 MN10-3860, 1885 Douglas Dr. Northward., Golden Valley, MN
55422, or whether a replacement product tin be sent to you.
This warranty does not embrace removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer.
Honeywell'south sole responsibleness shall be to repair or replace the product within the terms stated to a higher place. HONEYWELL SHALL Not BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL Damages RESULTING, DIRECTLY OR INDIRECTLY, FROM Whatsoever BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR Whatever OTHER FAILURE OF THIS Product. Some states do not allow the exclusion or limitation of incidental or consequential amercement, so this limitation may not apply to you.
THIS WARRANTY IS THE Just EXPRESS WARRANTY HONEYWELL MAKES ON
THIS Production. THE Elapsing OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE One-YEAR Duration OF THIS WARRANTY.
Some states do non allow limitations on how long an implied warranty lasts, then the above limitation may not apply to you. This warranty gives y'all specific legal rights, and yous may have other rights which vary from state to state.
If you have any questions concerning this warranty, please write Honeywell Client Relations, 1985 Douglas Dr, Golden Valley, MN 55422 or call 1-800-468-1502.
Other top honeywell transmission'due south:
- Honeywell Programmable Thermostat T6 Pro Installation Guide
- Honeywell Programmable Thermostat Owner'southward Transmission
- Honeywell T3M Digital Programmable Thermostat User Guide
Honeywell Programmable Thermostat Owner's Manual
Click to Read More Honeywell Manuals
Documents / Resources
Honeywell Programmable Thermostat [pdf] Owner's Manual Programmable, Thermostat, Honeywell, RTH6350, RTH6450, RET93E, RET95E | |
Honeywell Programmable Thermostat [pdf] User Guide Programmable, Thermostat, Honeywell, RTH7400, RTH7500 Series | |
Honeywell Programmable Thermostat [pdf] User Guide Programmable, Thermostat, RTH7400, RTH7500 Series, Honeywell | |
Honeywell Programmable Thermostat [pdf] Owner's Manual Programmable, Thermostat, RTH2300 Series, RTH221 Series, Honeywell | |
Honeywell Programmable Thermostat [pdf] Owner'south Manual Honeywell, Programmable, Thermostat, RTHL2310, RTHL221, Serial |
Source: https://manuals.plus/honeywell/programmable-thermostat-manual
0 Response to "How To Set Honeywell Programmable Thermostat"
Post a Comment